| Parameter |
Description |
Min. |
Max. |
Unit |
| Supply voltage |
Derived from computer serial port |
7 |
15 |
V |
| Supply current |
Derived from computer serial port |
2 |
5 |
mA |
| NMEA in/out |
|
|
|
|
| Input voltage tolerance |
Continuous operation |
-15 |
+15 |
V |
| |
Short term operation (< 1 sec) |
-35 |
+35 |
V |
| Differential input voltage |
Required level for data to be detected |
1.8 |
- |
V |
| Output voltage |
Dependent on computer serial port |
+/-5 |
+/-15 |
V |
| Output current |
Dependent on computer serial port |
- |
10 |
mA |
| Input to output protection |
Full Galvanic Opto-isolation |
- |
2000 |
V |
| RS232 in/out |
|
|
|
|
| Input voltage tolerance |
|
-15 |
+15 |
V |
| Input voltage threshold |
Logical LOW |
0.8 |
1.2 |
V |
| |
Logical HIGH |
1.7 |
2.8 |
V |
| Output voltage range |
3k ohm load, 'V' = RS232 port voltage |
-V |
+V |
V |
| Output resistance |
Output voltage swing +/- 2V |
200 |
- |
ohms |
| General |
|
|
|
|
| Baud rate |
|
2400 |
57600 |
bps |
| Ambient temperature |
|
-20 |
+70 |
°C |
|
| |