| Parameter |
Description |
Min. |
Max. |
Unit |
| Supply voltage |
|
10 |
35 |
V |
| Supply current |
Supply voltage 12v (no load) - 360 mWatts |
32 |
34 |
mA |
| |
Supply voltage 24v (no load) |
17 |
18 |
mA |
| Opto-isolated in |
|
|
|
|
| Input voltage tolerance |
Continuous operation |
-15 |
+15 |
V |
| |
Short term operation (< 1 sec) |
-35 |
+35 |
V |
| Differential input voltage |
Required level for data to be detected |
1.8 |
- |
V |
| Input current |
|
- |
2 |
mA |
| Input to Ground |
Full Galvanic Opto-isolation protection |
- |
2500 |
V |
| Baud rate |
Confgurable Baud rates |
4800 |
57600 |
bps |
| Data propagation delay |
Time taken from input to output |
1 |
100 |
msec |
| ISO-Drive out |
NMEA 0183 version 1-3 & PC Serial |
|
|
|
| Output current |
RS485 / RS422 / RS232 compatible |
- |
22 |
mA |
| Differential output voltage |
100 ohm load |
2.1 |
- |
V |
| Output to Ground |
Full Galvanic isolation protection |
- |
1500 |
V |
| Output to Output |
Full Galvanic isolation protection |
- |
1500 |
V |
| Baud rate |
Configurable Baud rates |
4800 |
115200 |
bps |
| USB interface |
(NDC-4-USB only) |
|
|
|
| Interface version |
USB v1.1 (fully compatible with USB v2.0) |
|
|
|
| General |
|
|
|
|
| Ambient temperature |
|
-20 |
+70 |
°C |
| Guarantee |
Extended Actisense guarantee |
- |
3 |
Years |
|
| |