NMEA 2000 Gateway NGW-1
 
 
Parameter Description Min. Max. Unit
NMEA 2000 bus power All models      
Bus voltage   10 35 V
Bus power Supply voltage 12v-24v (no load) 360 390 mWatt
NMEA 2000 in/out All models      
Input to Ground Full Galvanic Opto-isolation protection - 2500 V
Baud rate Fixed BPS / Baud rate 250000 250000 bps
USB Comms in/out NGW-1-USB model only      
Input to Ground Full Galvanic Opto-isolation protection - 2500 V
Baud rate Configurable Baud rate 4800 115200 bps
Opto-isolated in NGW-1 model only      
Input voltage tolerance Continuous operation -15 +15 V
  Short term operation (< 1 sec) -35 +35 V
Differential input voltage Required level for data to be detected 1.8 - V
Input current   - 2 mA
Input to Ground Full Galvanic Opto-isolation protection - 2500 V
Baud rate Configurable Baud rate 4800 115200 bps
ISO-Drive out NGW-1 model only      
Output current RS485 / RS422 / RS232 compatible - 20 mA
Differential output voltage 100 ohm load 2.1 - V
Output to Ground Full Galvanic isolation protection - 1500 V
Baud rate Configurable Baud rate 4800 115200 bps
General        
Ambient temperature   -20 +70 °C
Guarantee Extended Actisense guarantee - 3 Years