NMEA Multiplexer / Combiner NDC-1
 
 
Parameter Description Min. Max. Unit
Supply voltage   8 35 V
Supply current Supply voltage 12v (no load) 110 120 mA
  Supply voltage 24v (no load) 70 75 mA
NMEA in/out        
Input voltage tolerance Continuous operation -15 +15 V
  Short term operation (< 1 sec) -35 +35 V
Differential input voltage Required level for data to be detected 1.8 - V
Output current RS485 / RS422 compatible - 32 mA
Input to output protection Full Galvanic Opto-isolation - 2000 V
Baud rate Configurable Baud rate 4800 38400 bps
Data propagation delay   1 100 msec
RS232 in/out        
Input voltage tolerance   -15 +15 V
Input voltage threshold Logical LOW 0.8 1.2 V
  Logical HIGH 1.7 2.8 V
Output resistance Output voltage swing +/- 2V 300 - ohms
Baud rate Configurable Baud rate 4800 115200 bps
Data propagation delay   1 100 msec
General        
Ambient temperature   -20 +70 °C