| Parameter |
Description |
Min. |
Max. |
Unit |
| Supply voltage |
|
8 |
35 |
V |
| Supply current |
Supply voltage 12v (Min. load, Max. load) |
6 |
70 |
mA |
| |
Supply voltage 24v (Min. load, Max. load) |
4.8 |
40 |
mA |
| NMEA in |
|
|
|
|
| Input voltage tolerance |
Continuous operation |
-15 |
+15 |
V |
| |
Short term operation (< 1 sec) |
-35 |
+35 |
V |
| Differential input voltage |
Required level for data to be detected |
1.8 |
- |
V |
| Input current |
|
- |
2 |
mA |
| Input to output protection |
Full Galvanic Opto-isolation |
- |
2000 |
V |
| RS485 / RS422 out |
NMEA 0183 version 2-3 |
|
|
|
| Output current |
RS485 / RS422 compatible |
15 |
40 |
mA |
| Differential output voltage |
50 ohm load |
2 |
- |
V |
| RS232 out |
NMEA 0183 version 1-3 & PC serial |
|
|
|
| Output current |
|
5 |
10 |
mA |
| Output voltage |
3k ohm load |
+/-5 |
- |
V |
| General |
|
|
|
|
| Baud rate |
|
- |
57600 |
bps |
| Ambient temperature |
|
-20 |
+70 |
°C |
|
| |