| Parameter |
Description |
Min. |
Max. |
Unit |
| Supply voltage |
|
11 |
28 |
V |
| Supply current |
Supply voltage 12v |
30 |
40 |
mA |
| |
Supply voltage 24v |
30 |
40 |
mA |
| NMEA in/out |
|
|
|
|
| Input voltage tolerance |
Continuous operation |
-15 |
+15 |
V |
| Differential input voltage |
Required level for data to be detected |
2.0 |
- |
V |
| Output current |
RS485 / RS422 compatible |
- |
10 |
mA |
| Baud rate |
Customisable (at engineering cost) |
4800 |
- |
bps |
| Data output rate |
Customisable (at engineering cost) |
- |
1 |
sec |
| Depth |
Sensor dependent (Configurable Cal) |
|
|
|
| Range (narrow beam) |
Airmar P66, P79, < 10 knots, ideal conditions |
0.3 |
200 |
metres |
| Range (wide beam) |
Airmar DT800, < 10 knots,
ideal conditions |
0.5 |
150 |
metres |
| Range (narrow beam) |
Airmar P66, P79, 10-40 knots, ideal conditions |
0.3 |
100 |
metres |
| Range (wide beam) |
Airmar DT800, 10-40 knots, ideal conditions |
0.5 |
100 |
metres |
| Speed |
Sensor dependent (Configurable Cal) |
|
|
|
| Range |
Airmar P66, DST800, calibrated 5 Hz / knot |
0.5 |
50 |
knots |
| Temperature |
Sensor dependent (Configurable Cal) |
|
|
|
| Range |
Airmar, calibrated 10k @ 25 °C |
-10 |
50 |
°C |
| General |
|
|
|
|
| Gland clamping range |
Cable diameters accommodated |
4.5 |
10 |
mm |
| Ambient temperature |
|
-20 |
+70 |
°C |
|
| |